Application Event Log for the License Manager - For Windows Only

In Windows systems, the local events related to applications and services are displayed in the Event Viewer.

To open the Event Viewer:

>Go to Start > Settings > Control Panel > Administrative Tools.

>Double-click the Event Viewer icon. The Event Viewer dialog box appears.

>Click the Application icon to view the events for all the applications run on your system.

NOTE   Sort the list as per the source. RMS specific messages are labeled as Sentinel RMS Development Kit License Manager. The event properties can be seen by right clicking an event in the list.

The following operations (categorized as errors, information, and warnings) are related to the Sentinel RMS License Manager as shown in the following table:

Category

Event ID

Message

Comment

Error

29

The Sentinel RMS License Manager was unable to open the specified log file.

During the License Manager initialization,opening of log files (usage and trace) failed.

Error

30

The Sentinel RMS License Manager was unable to open a socket.

During the License Manager initialization, could not find a socket.

Error

31

The Sentinel RMS License Manager detected another License Manager running on the same port.

During the License Manager initialization, the specified port is already in use.

Error

32

The Sentinel RMS License Manager was unable to bind to its socket.

During the License Manager initialization, socket bind error occurred.

Error
33 The Sentinel RMS License Manager was unable to open file <filepath>. The Windows system error number is 5. During the License Manager initialization.

Error

71

The Sentinel RMS License Manager failed to start because option <invalid-option> is an invalid parameter. Valid parameters are: <option-symbol option-name>Example:The Sentinel RMS License Manager failed to start because option <invalid-option> is invalid parameter. Valid parameters are: [-s License-file] [-e License-configuration-file] [-l Usage-log-file] [-z Log-file-size] [-x No-log-file-truncation] [-u Group-reservations-file] [-port Port-number] [-rlf Redundant-license-file] [-com Percentage-of-commuter-keys-allowed] [-lfe Encryption-level <1..4>] [-us Upgrade-license-file] [-f Trace-message-file] [-tr Trace-level]

During the License Manager startup, invalid startup option.

Information

76

Sentinel RMS License Manager, Version <8.x.x> Copyright (c) Thales, Inc. The license manager was successfully started on host <host name>.

Successful service start.

Error

77

The Sentinel RMS License Manager was unable to start because an unknown error has occurred.

During the License Manager initialization, an unknown error occurred.

Warning

80

The Sentinel RMS License Manager service on host <host name> has been paused.

Successful service pause.

Information

81

The Sentinel RMS License Manager service on host <host name> has been resumed.

Successful service resume (after pause).

Error

82

The Sentinel RMS License Manager service on host <host name> has been stopped.

The License Manager stopped due to an error. Note this message will be printed

Warning

83

The Sentinel RMS License Manager was unable to open the license file <license store file name>. No applications are licensed.

During the License Manager initialization or adding/validating the client library API function, the license could not be installed due to failure in accessing license store, such as inability to access the file.

Warning

84

The Sentinel RMS License Manager received the following invalid license: <license code>. Reason: <Reason>.

When the license table is being loaded

after the License Manager initialization, the license is found invalid. This could be due to many reasons, such as: an invalid license version, a standalone license being added on a License Manager, software vendor ID mismatch, a redundant license being added to a non-redundant License Manager, clock

tampering detected and so on.

Warning

85

The Sentinel RMS License Manager was unable to initialize from the license code <license code>.

During the License Manager initialization or adding/validating the client library API function—the license could not be installed due to an internal error.

Warning

86

The Sentinel RMS License Manager is not authorized to license the feature <feature name> on this machine. The license key code <license code> has not been added to the license manager registry.

During the License Manager initialization or adding/validating the client library API function, the license could not be installed due to some reason(s), such locking code mismatch.

Information

90

The Sentinel RMS License Manager shut down.

Successful service shut-down.

Warning

108

In Sentinel RMS License Manager, license revocation-related initialization failed.

During the License Manager startup when a revoke license request is made, the revoke persistence database is found corrupt and unrecoverable.

Error

109

The Sentinel RMS License Manager failed to start.No value is specified for option <invalid-option>

During the License Manager startup, the startup option was passed without a value. For example, the -z option is passed without any value.

Error

110

The Sentinel RMS License Manager failed to start.Invalid value is specified for option <invalid-option>.

During the License Manager startup, the startup option value passed is incorrect, which led to initialization failure.

Information

111

The Sentinel RMS License Manager has set default value <default value> for server option <server option> because of invalid value specified.

During the License Manager startup, the option was not set, or an invalid value was passed. Hence, the default value is used. For example, for port 5093 is used.

Error

112

The Sentinel RMS License Manager was unable to compute machine locking code.

When the license table is being loaded after the License Manager initialization, failed to compute the locking code of the system, where the License Manager is running.

Information

113

The Sentinel RMS License Manager is switching over the trace file because of maximum size reached. Backed up file name is <backed up file name>.

During the License Manager execution, if tracing is enabled and -z option is set, the maximum file size is reached. The automatic switchover of files takes place.

Warning

114

The License Manager (service) has faced input output error during tracing.

During execution, if tracing is enabled, an input/output error occurs.

Information

115

The Sentinel RMS License Manager is starting as non-redundant License Manager.

During execution, if no/invalid redundant file is specified in -rlf server option.

Error

116

The Sentinel RMS License Manager was stopped by the license install policy

The license installation policy of the customized License Manager chose to stop the License Manager. The corresponding license string (that could not be installed/loaded) can be found under the Event details.

Error

117

The Sentinel RMS License Manager failed to start, either vendor identifier not set or the server has been built with incorrect server library.

The Sentinel RMS License Manager failed to start as either vendor identifier is not set or the License Manager is built with an incorrect library.

Information

118

The Sentinel RMS License Manager has started with the default socket buffer(IPv6) size value set to 8192 bytes.


or


The Sentinel RMS License Manager has started with default socket buffer(IPv4) size value set to 8192 bytes.

An invalid value was specified as the multiplier with -sbm option.

 

Use non zero, positive numerical values with this License Manager Startup option.

Error

119

Service name does not match with the installed service. The Sentinel RMS License Manager you are trying to start has a different "service name" from the installed service.