How to Clear the "Cloned" Status for a Product License
If a Product license is disabled because it has been identified as "cloned", proceed as follows to re-enable the license:
>For a Product license generated using Sentinel LDK-EMS:
a.In Sentinel LDK-EMS, check in the C2V file from the disabled Product license, and click Clear Clone. Sentinel LDK-EMS generates a V2C file.
b.Return the V2C file to the customer to apply on the machine where the Product license was disabled.
>For a Product license generated using Sentinel License Generation API: Use the provided function to clear the "cloned" status for the license. For more information, see the Sentinel License Generation API Reference.
NOTE To clear clone detection for a Product with a custom clone protection scheme:
>In cases where the vendor selected two or more clone protection criteria, at least one of the selected criteria must match in the reference and system fingerprints.